Secure Checkout
Si-CA 130 instrument only (smart phone or mobil device not included)
New Si-CA 130 - 2 Gas Series Flue Gas Combustion Analyzer, Measure Oxygen, Carbon Dioxide

Thumbnail Filmstrip of New Si-CA 130 - 2 Gas Series Flue Gas Combustion Analyzer, Measure Oxygen, Carbon Dioxide Images

    New Si-CA 130 - 2 Gas Series Flue Gas Combustion Analyzer, Measure Oxygen, Carbon Dioxide

    Overview

    The New Si-CA-130 - 2 Gas - Flue Gas Combustion Analyzer is the latest in combustion analysis technology for residential and commercial combustion analyzer. The New Si-CA-130 - 2 Gas Combustion Analyzers offers everything heating engineers need to inspect and maintain residential and Light commercial boilers. Measures Oxygen (O2), Carbon Monoxide (CO) and calcuated Carbon Dioxide (CO2) along with all of the necessary temperature, draft, and pressure measurements for combustion efficiency analysis. The New updated Sauermann app for iOS & Android mobile devices provides fast, easy wireless connection, report creation in PDF, CSV (for Excel) and XML formats and more.
    Features
    • 4.3" (10.9 cm) Large Color Touch Screen with Graphing
    • Combustion Analyzer for Oxygen (O2), Carbon Dioxide (CO2), Carbon Monoxide (CO), Excess Air, Efficiency along with all of the necessary temperature, draft, and pressure measurements
    • CO Sensor 0 to 8000 ppm
    • Standard Flue Gas Test Probe 7" (180mm) with 6.5' (2m) dual hose
    • Data management with automatic logging and report creation trough app/PC software
    • Quick and easy pump On/Off control
    • Customizable gas analysis screen
    • Field replaceable precalibrated sensors
    • PC software with wireless and USB connectivity
    Price Starting At:
    $1,560.00
    Need help? Contact us with questions.

      Shipping Estimated Shipping 1 to 2 Week
    Si-CA 130 - 2 Gas - Flue Gas Combustion Analyzer Series Measurement Specifications
    Parameter Sensor Type Range Resolution Accuracy
    Oxygen (O2) Electrochemical 0 to 25% 0.01% ±0.2% Volume
    Carbon Monoxide (CO) Electrochemical 0 to 8000 ppm 1ppm ±8 ppm <160 ppm
    ±5%rdg up to 2000 ppm
    ±10 % rdg for >2000 ppm
    Carbon Dioxide (CO2) Calculated 0 to 99.9% 0.1%  ------
    Flue Gas Temperature
    (Accuracy given for the analyzer only)
    Type K Thermocouple -4 to 2282°F
    -20 to 1250°C
    0.1°F/°C ±3.6°F or ±0.5% rdg
    ± 2°C or ±0.5% rdg
    Air temperature NTC or Type K Thermocouple -4 to +248°F
    -20 to 120°C
    0.1°F/°C ±3.6°F
    ±2°C
    Differential Temperature Calculated 0 to 2282°F (0 to 1250°C) 0.1°F/°C  -----
    Pressure/Draft Semiconductor -80 to +80 inH2O
    -200 to +200mBar
    0.001 inHO
    0.01mBar
    ±1% rdg ±0.012 inH2O
    ±1% rdg ±0.03 mbar
    High Accuracy Draft Semiconductor 500 Pa 0.1 Pa ±0.5 Pa < 10Pa
    ±3Pa up to 150 Pa
    ±2% rdg > 150 Pa
    Excess Air Calculated 0 to 999% 1%  
    Efficiency (For Higher Heating Value) Calculated 0 to 100%(Gross/HHV) 0.1%  
    Efficiency Condensation (For Lower Heating Value) Calculated 0 to 125%(Net/LHV) 0.1%  
    Stack Gas Velocity Calculated 0 to 99 m/s
    0 to 19,500 fpm
    0.1% m/s
    1 fpm
     
    Si-CA 130 - 2 Gas Series Flue Gas Combustion Analyzer General Specifications
    Display Large Color Touch Screen with Graphing 4.3" (10.9 cm), 480 x 272 pixels
    Flue Gas Test Probe 7" (180 mm) Long, 6.5' (2 m) Dual Hose, Temperature Range 1472°F (800°C)
    Keypad 1 Key On/Off
    Communications Connection Wireless: class 2 range, range frequency from 2402 MHz to 2480 MHz with a transmit power of 1 dBm.
    Range up to 15 m (50 ft), depending on smartphone radio strength
    Minimum required versions: Android 5.0, iOS 12.4, BLE 4.0
    Power Supply Rechargeable battery, USB power supply
    Li-Ion 5100 mA/h 3.6 V battery
    Power supply voltage of the mains unit: 100 to 240 Vac, 50 to 60 Hz
    Mains unit: 5 Vdc/2A
    Battery Life/Charging Time > 8 hours Charging time: Fully charge: <6.5 hours; 50%: <2.5 hours
    Operating Temperature 23 to 113°F (-5°C to +45°C)
    Storage Temperature -4 to 122°F (-20°C to +50°C)
    Operating Humidity Range <85% RH (In Non-Condensing Conditions)
    Air Pressure Atmospheric Maximum altitude: 6561' (2000m)
    Outer Dimensions Analyzer 7.5 x 3.5 x 1.6 inches (19.4 x 9.9 x 4.9 cm) (Height x Width x Depth)
    Analyzer Material ABS-PC
    Analyzer Protection IP 42
    Analyzer Weight Approx. 12.3 Oz
    Languages English, French, German, Spanish, Italian, Portuguese
    Si-CA 130 - Apps and PC Software Features
    • Free apps for iOS & Android mobile devices
    • PC software with USB & wireless connectivity
    • Fast, easy wireless connection
    • Remote live view of combustion analysis data as list or graph
    • Remote control to change settings
    • Data saving, including automatic logging
    • Report creation in PDF, CSV (for Excel) and XML formats
    • Databases for customers, operators & equipment


    Each Si-CA 130 - 2 Gas Combustion Analyzer Kit includes Analyzer with Oxygen (O2), Carbon Monoxide (CO) Sensors, Protective rubber holster, 7" (180 mm), Flue gas probe with 6.5' (2 m) dual hose probe rated to 1472°F (800°C), Water trap with filter, AC power supply/charger, USB cable, Mobile app and PC Software, Internal wireless communication module, Carrying case, Quick Start Guide, Calibration certificate.