https://www.tnp-instruuments.com/021a5a61a75c4103ae965951895bb658
Secure Checkout
New RHT-DM Duct Mounted Humidity, Dew Point and Temperature Transmitter

Thumbnail Filmstrip of New RHT-DM Duct Mounted Humidity, Dew Point and Temperature Transmitter Images

    New RHT-DM Duct Mounted Humidity, Dew Point and Temperature Transmitter

    Overview

    The RHT-DM duct mounted temperature and humidity transmitters incorporate the best high accuracy and great stability relative humidity and temperature sensors. The RHT-DM convert the measured values into linear 4 to 20 mA signals or optionally 0 to 10 Vdc output. The microprocessor based circuit enables full configuration of output range when used with the optional TxConfig PC interface and the Windows® based software. The humidity signal can be configured to either relative humidity or dew point output.
    Features
    • New Two Probe Materials 316 Stainless Steet Or PA-GF
    • Two Probe Lenghts Available 150mm or 250mm
    • Microprocessor Based Humidity and Temperature Transmitter
    • Field Programable with Optional TxConfig-USB configuration interface and SigNow software
    • Two-wire loop powered 4 to 20mA
    • Isolated 4 to 20mA outputs
    • Accuracy Relative Humidity: ±3 % RH @ 77°F (25°C)
    • Temperature Accuracy ±0.72°F (0.4°C) @ 77°F (25°C)
    • Power 12Vdc to 30Vdc
    • Electronic circuit case IP65; Sensors housing IP40
    Price Starting At:
    $171.00
    Need help? Contact us with questions.

      Shipping Estimated Shipping 1 to 4 Weeks
    RHT-DM Humidity Measurement Specifications
    Sensor Measuring Range Temperature: -40 to 248°F (-40 to 120°C)
    Relative Humidity: 0 to 100% RH (non-condensing)
    Dew Point: -148 to 217.4°F (-100 to 103°C)
    Response Time: Temperature: up to 30s @ 77°F (25°C) with air moving at 1 m/s or 3.28 ft/s
    Humidity: up to 8s @ 77°F (25°C) with air moving at 1 m/s or 3.28 ft/s
    Measurement Accuracy: Temmperature: ±0.72°F (0.4°C) @ 77°F (25°C)
    Relative Humidity: ±3 % RH @ 77°F (25°C)
    Analog Outputs 4 to 20 mA or 20 to 4 mA, 2-wire type, loop-powered
    Analog Outputs Resolution: 0.0008 mA
    Operating Temperature -4 to 158°F (-20 to 70°V), 0 to 95% RH
    Connections:> Internal terminal block, via cable glands
    Housing Material Housing (WM/DM models) in PA-GF
    Housing and Sensor Ratings Enclosure: IP65, Sensor: IP40
    Configuration Optional TxConfig-USB configuration interface and SigNow software for Windows or Android
    RHT-WM General Specifications
    Power Supply 12Vdc to 30Vdc
    Outputs 4 to 20mA 2-wire loop power supply
    Output Load RL (max. in Ohms) = (Vdc - 12)/ 0.02, where: Vdc = Supply Voltage in Volts.
    OUT1 and OUT2 Output Resolution 0.0008 mA (4-20 mA)
    Isolation between outputs Isolated 4-20 mA outputs.
    Reverse Polarity Protection Yes
    Cable Gland Compress fitting PG7
    Case Dimension 2.8" (70mm) W x 2.4" (60mm) H with Probe 3.1" (78.5mm)
    SigNow software for Windows or Android may be downloaded at the manufactures web site at https://www.novusautomation.com/en/website/software