Secure Checkout
S6000-6DSC Six Gas Combustion Gas Emissions Analyzer Measure O2, CO, NO/NOx, NO2, SO2, & CxHy/HC

Thumbnail Filmstrip of S6000-6DSC Six Gas Combustion Gas Emissions Analyzer Measure O2, CO, NO/NOx, NO2, SO2, & CxHy/HC Images

    S6000-6DSC Six Gas Combustion Gas Emissions Analyzer Measure O2, CO, NO/NOx, NO2, SO2, & CxHy/HC

    Overview

    The S6000-6DSC Six Gas Industrial Portable Combustion Gas & Emissions Analyzer is a commercial and industrial gas analyzer that is a valuable tool designed for emissions monitoring and maintenance and tuning of combustion processes including boilers, burners, gas and diesel engines, turbines, furnaces, kilns, heaters, and laboratory analysis.
    Features
    • Measure Oxygen (O2), Carbon Monoxide (CO), Nitric Oxide (NO), Nitrogen Oxides (NOx), NO2, Sulfur Dioxide (SO2), CxHy/HC and Calculates Carbon Dioxide (CO2)
    • Full Color Graphic Display Screen
    • Built-In Impact Printer (non-fading paper)
    • Internal Memory (up to 2000 tests) Data Logging with time and date stamp
    • PC Software Package with USB & Bluetooth Communications
    • Dilution Pump For CO Auto-Range Measurements Up To 50,000 ppm
    • Draft and Differential Pressure Measurements
    • 12 Selectable Fuel/Oil Types Including Bio-Heat 5%
    • Efficiency, Excess Air, and CO2 Calculations
    • Stack Gas and Air Temperature Measurements
    • Unbreakable Metal Hose Connectors
    • ALL Gas Sensors are Pre-Calibrated and Field Replaceable
    Price Starting At:
    $6,600.00
    Need help? Contact us with questions.

      Shipping Estimated Shipping 1 to 2 weeks.
    S6000-6DSC Combustion Analyzer Measurement Specifications
    Parameter Sensor Range Resolutoin Accuracy
    Oxygen (O2) Electrochemical 0 to 25% 0.1% ±0.2% volume
    Carbon Monoxide (CO)
    H2 Compensated
    WITH Built-in NOx Filter
    Electrochemical 0 to 8000 ppm 1 ppm ±8 ppm <200ppm
    ±5% rdg uo to 2000ppm
    ±10% rdg for >2000 ppm
    Carbon Monoxide (CO) DILUTED Electrochemical 0.8% to 10.00% 0.1% ±10% rdg
    Carbon Dioxide (CO2) Calculated 0 to 99.9% 0.1% -
    Nitric Oxide (NO) Electrochemical 0 to 5000 ppm 1 ppm ±5 ppm <100ppm
    ±5% rdg for >100ppm
    NOx Measurement Calculated 0 to 5000 ppm 1 ppm -
    Nitrogen Dioxid (NO2) Electrochemical 0 to 1000 ppm 1 ppm ±5 ppm <100ppm
    ±5% rdg for >100ppm
    SulFur Dioxide (SO2) Electrochemical 0 to 5000 ppm 1 ppm ±5 ppm <100ppm
    ±5% rdg for >100ppm
    Hydrocarbons CxHy (HC) Pellistor 0 to 5% 0.01% ±5^ Full Scale
    Optional Low NO and/or Low NO2 Electrochemical 0 to 100.0 ppm 0.1 ppm ±1.5 ppm <40.0ppm
    ±5% rdg for >100ppm)
    Optional Low Sulfer Dioxide (S02) Electrochemical 0 to 100.0 ppm 0.1 ppm ±5% full scale
    Temperature Air Pt100 -4 to 248°F (-20 to 120°C) 0.1°F or °C ±1°F/°C
    Temperature Gas Type K Thermocouple -4 to 2280°F (-20°C to 1250°C) 0.1°F or 0.1°C ±2°F°C
    Differential Temperature Calculated -10 to 1830°F (-23°C to 999°C) 1°F or °C ±0.5 °C (-20 to 100 °C)
    ±0.5% rdg (101 to 1250°C)
    Pressure/Draft Semiconductor -4 to 80 inH2O
    -10 to 200mbar
    0.001 inH2O
    0.01mbar
    ±1% rdg
    Combustion Efficiency Calculated 0 to 100% 0.1% -
    Excess Air Calculated 0 to 850% 1% -
    Optional Low NO, Low NO2, and Low SO2 are available please call 914-673-0333 for price and availability
    S6000-6DSC General Specifications
    Display Graphic 272 x 480 pixels, backlit, color TFT 4.3"
    Printer Thermal integrated with easy loading paper and sensor for the presence of paper
    Printout heading 4 lines x 24 characters, customizable by the user
    Printer power supply From the analyzer battery pack
    Internal data storage 2000 complete data analyses including date, time and client’s name
    Communications port USB with mini-USB connector
    Bluetooth Communication Communication range: <100 meters (free field)
    Power Supply Rechargeable battery, Li-Ion battery pack with internal protection circuit
    Battery life 12 hours of continuous operation (printing excluded)
    Charging time 5 hours to recharge from 0% to 90%
    Operating Temperature 23 to 113°F (-5°C to +45°C)
    Storage Temperature -4 to 122°F (-20°C to +50°C)
    Operating humidity range 20% to 80% RH
    Air pressure Atmospheric
    Outer dimensions analyzer 3.5 x 12.2 x 2.4 in (31 x 9 x 6 cm) (H x W x D)
    Analyzer Only Weight ~2 lbs. (~ 1 Kg)
    S6000-6DSC Combustion Analyzer Include: Base unit with 5 sensors Oxygen O2 (0-25%), CO (0-8000ppm), NO/NOx (0-5000ppm), NO2 (0-1000ppm), SO2 (0-5000ppm) and CxHy/HC (0-5%) gas sensors, Built-In Printer, Draft & Differential Pressure, Temperature Measurements, Calculation for CO2, Efficiency & Excess Air, Li-Ion Rechargeable Batteries & AC Charger, 12" (300mm), 1470°F (800°C) max, 10' (3m) Dual Hose Gas Sampling Probe & Hoses, Water Trap with Filter Cartridge, Magnetic Rubber Holster, 2000 Test Internal Memory, PC Software & USB Cable, QR Code Smartphone Apps (iOS & Android), Bluetooth Module (Internal), Operating Manual, Calibration Certificate, ABS Hard Plastic Carrying Case.