Your Cart (0)
New! DC711 Flue Gas Analyzer. When Combined with TPI View App: Easy, Affordable & Remote Operation!
DC711: instrument only (smart phone not included)Operate remotely via Bluetooth using your Smartphone or tablet** and the free Test Product International Android or iOS app. No need for long probe hoses: be at the control center with your smartphone while the DC711 does the work at the stack!
New DC711 Combustion Analyzer Measure Oxygen and Carbon Monoxide Upgradeable to Measure Nitric Oxide
Overview
- Four Models to Choose From
- Upgradeable to measure NO and calculate NOx.
- Operate remotely via Bluetooth using your Smartphone or tablet and the free TPI app. No need for long probe hoses - you can be at the control center with your smartphone, while the DC711 does the work at the stack.
- The free TPI app provides on-site reports which can instantly be emailed and stored without the need for paper or printers.
- 24-Hour real-time clock for accurate documentation
- Powerful magnetic and/or hook mounting.
- Durable, rugged and sealed housing
- Flue Gas Analysis:Measure Carbon Monoxide, Oxygen and Temperature Differential
- Calculate CO2, CO Air Free, Excess Air, and Combustion Efficiency
- Built-in manometer for performing pressure and draft measurements
DC711 Combustion Analyzer Measurement Specifications
Parameter | Range | Resolutoin | Accuracy |
---|---|---|---|
Oxygen (02) | 0 to 25% | 0.1% | ±0.3% |
Carbon Monoxide (CO) (Low) | 0 to 10,000 ppm | 1 ppm | ±5ppm or 5% of reading whichever is greater |
Carbon Monoxide (CO) (High) IF Fitted | 0 to 100,000 ppm | 0.001% | >=100ppm ±5% |
Nitric Oxide IF Fitted | 0 to 5000 ppm | 1 ppm | ±5ppm or ±5% (±10% (>1000ppm)) |
Carbon Dioxide (CO2) Calculated | 0 to 25% | 0.1% | Calculated Value |
CO/CO2 Ratio | 0 to 0.999 | 0.001 | Calculated Value |
Combustion Efficiency | 0 to 100% | 0.1% | Calculated Value |
Temperature Type K Thermocouple | Maximum Temperature 1472°F (800°C) | 1°F or °C | ±0.3% of of fullscale, ±2°F (1°C) |
Pre-programmed Fuels | Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal, Coke, Butane, Wood, Bagasse |
DC711 Flue Temperature Probe Specifications
Construction | Pistol Grip with Stainless Steel Shaft |
Hose Length | 8.2’ (2500mm) |
Insertion Length | 7.9" (200mm) |
'K' Type Thermocouple Accuracy | ±0.3% of of fullscale, ±2°F (1°C) |
Maximum Temperature | 1472°F (800°C) |
Pre-programmed Fuels | Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal, Coke, Butane, Wood, Bagasse |
DC711 Combustion Analyzer Instrument Specifications
Operating Temperature Range | +14°F to +122°F (-10°C to +50°C) |
Selectable Fuels | Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal, Coke, Butane, Wood, Bagasse |
Temperature Measurements | Input Type: K-Type thermocouple Range: -58°F to 1832°F (-50°C to 1000°C)* Resolution: 1°F (1°C) Accuracy:±(0.3% of rdg + 2°F) or ±(0.3% of rdg + 1°C) |
Pressure Measurements | mbar, psi, inH2O, mmH2O, kPa, hPa, inHg, mmHg, mH2O Range: -150 mbar to + 160 mbar, -15 kPa to + 15 kPa, -60 inH2O to 60 inH2O Resolution: 0.001 mbar (0~9.999 mbar), 0.01 mbar (10.00~149.99 mbar Accuracy: ± 0.5 mbar FSD |
Display | Backlit Graphic LCD |
Data Storage | 100 sets of readings (30 sets for CO Build Up), multiple pages |
Time and Date | 24 Hour Real Time Clock |
Battery Type/ Life | Rechargeable Li-ion 3.7V >6 Hours |
Charger Input | USB "C" Type Connection |
Dimensions (W x L x D) | 7.28" (185mm) x 4.92" (125mm) x 2.56" (65mm) |
Print Capability | Yes, via Optional A740BT Bluetooth printer (A740BT) |
DC711 Flue Gas Analyze includes Soft Carrying Case, Flue Temperature Sampling Probe, In-Line Filter / Water Trap installed on Flue probe, Disc water filter installed in water trap, Spare In-Line Filter, Ambient Air Temperature Probe, USB “C” Charger Cable, Mini Pump Protection Filter Assembly, Instruction Manual