C50 Multifunction Temperature and Process Calibrator
Overview
The C50 Multifuncton Calibrator is the ideal tool for advanced process maintenance and use on test bench in all industries. Suitable for all field and lab measurements, it can simultaneously measure and generate over two isolated channels various signals of temperature, resistance, process and frequency in one single instrument.Features
- Simultaneously Measures and Simulates 14 Thermocouple Types, 12 RTD, Currecnt, Voltage and Frequency
- Values displayed in °C, °F, Ω, Hz
- Advanced data exploitation: Scaling, relative measurement, simulation of ramps and steps, synthetizer, square root, statistical functions
- C50 Integrates "Easyconnect" Terminals
- 240 x 320 Pixel Liquid Crystal Graphical Display with Backlite
- Display of minimum, maximum and average value
- Simple and cyclical ramp generation
- IP54 according to EN60529
Price Starting At:
$2,799.00
$2,799.00
Shipping Estimated Shipping 1 to 4 Weeks
C50 Multifunction Temperature and Process Calibrator Specifications
Display | 240 x 320 pixel liquid crystal graphical display with backlite and contrast control |
Operating Temperature | -10 to 50°C (+14 to 122°F) |
Operating Humidity | 20 to 80% non-condensing |
Storage Temperature | -30°C to +60°C (-22°F to 140°F) |
Power Requirements | Ni-MH, 1.8 Ah rechargeable batteries |
Battery Life | 5 to 10 hours, depending on the functions used |
CE - EMC | EN50082-1 and EN55022: 1994 Class B |
Serial Communications | USB |
Safety Protections | Electronic protection up to 250 V for ‘voltage’ wires Fuse protection for ‘current’ wires Protection against ‘current’ circuit breaking during inductive resistance measurements |
EMC conformity Immunity | EN 61000-4-2, EN 61000-4-3, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11 |
Dimensions | 8.3" W x 4.3" W x 2" D (210 x 110 x 50mm) |
Weight | 2 lbs. (900 g) | Other | Waterproof to IP 54 in accordance with standard EN 60529 |
C50 Thermocouple Measurement and Simulation Range Specification Table
Download the Data Specification Sheet or the Users Manual for Complete Range and Accuracy Tables
Sensor Type | Temperature Input Range | Temperature Input Resloution | Accuracy 1 Year (Measurement) | Temperature Output Range | Temperature Output Resloution | Accuracy 1 Year (Simulation) |
---|---|---|---|---|---|---|
Type J | -210 to +1200°C (-346 to +2192°F) | 0.05°C | 0.013% RDG + 0.07°C(0.13°F) | -210 to +1200°C (-346 to +2192°F) | 0.05°C (0.09°F) | 0.013% RDG + 0.07°C(0.13°F) |
Type K | -250 to +1372°C (-418 to +2501°F) | 0.05°C (0.09°F) | 0.013% RDG + 0.08°C(0.14°F) | -240 to +1372°C (-400 to +2501°F) | 0.2°C (0.36°F) | 0.013% RDG + 0.08°C(0.14°F) |
Type T | -250 to +400°C (-418 to +752°F) | 0.2°C (0.36°F) | 0.013% RDG + 0.08°C(0.144°F) | -240 to +400°C (-418 to +752°F) | 0.2°C (0.36°F) | 0.013% RDG + 0.08°C(0.144°F) |
Type E | -250 to +1000°C (-418 to +1832°F) | 0.1°C (0.18°F) | 0.013% RDG + 0.05°C(0.09°F) | -250 to +1000°C (-418 to +1832°F) | 0.1°C (0.18°F) | 0.013% RDG + 0.05°C(0.09°F) |
Type R | -50 to +1768°C (-58 to +3214°F) | 0.5°C (0.9°F) | 0.013% RDG + 0.2°C(0.36°F) | -50 to +1768°C (-58 to +3214°F) | 0.5°C (0.9°F) | 0.013% RDG +0.2°C(0.36°F) |
Type S | -50 to +1768°C (-58 to +3214°F) | 0.5°C (0.9°F) | 0.013% RDG + 0.25°C(0.45°F) | -50 to +1768°C (-58 to +3214°F) | 0.5°C (0.9°F) | 0.013% RDG +0.25°C(0.45°F) |
Type B | +400 to +1820°C (+752 to +3214°F) | 0.5°C (0.9°F) | 0.013% RDG + 0.25°C(0.45°F) | +400 to +1820°C (+752 to +3214°F) | 0.2°C (0.36°F) | 0.013% RDG +0.2°C(0.36°F) |
Type N | -240 to +1300°C (-400 to +2372°F) | 0.2°C (0.36°F) | 0.013% RDG + 0.15°C(0.108°F) | -240 to +1300°C (-400 to +2372°F) | 0.2°C (0.36°F) | 0.013% RDG + 0.06°C(0.108°F) |
Type C | -20 to +2310°C (+14 to +4190°F) | 0.1°C (0.18°F) | 0.013% RDG + 0.15°C(0.27°F) | -20 to +2310°C (+14 to +4190°F) | 0.1°C (0.18°F) | 0.013% RDG + 0.15°C(0.27°F) |
Type PLATINUM | -100 to +1400°C (-148 to +2552°F) | 0.05°C (0.18°F) | 0.3°C(0.54°F) | -100 to +1400°C (-148 to +2552°F) | 0.05°C (0.18°F) | 0.3°C(0.54°F) |
Type MO | 0 to +1375°C (+32 to +2507°F) | 0.05°C (0.18°F) | 0.013% RDG + 0.06°C(0.108°F) | 0 to +1375°C (+32 to +2507°F) | 0.05°C (0.18°F) | 0.013% RDG + 0.06°C(0.108°F) |
Type NiMo/NiCo | -50 to +1410°C (-58 to +2570°F) | 0.05°C (0.18°F) | 0.013% RDG + 0.30°C(0.54°F) | -50 to +1410°C (-58 to +2570°F)/td> | 0.05°C (0.18°F) | 0.013% RDG + 0.30°C(0.54°F) |
Type U | -200 to +660°C (-328 to +1220°F) | 0.05°C (0.09°F) | 0.15°C(0.27°F) | -200 to +600°C (-328 to +1112°F) | 0.05°C (0.09°F) | 0.15°C(0.27°F) |
Type L | -200 to +900°C (-328 to +1652°F) | 0.05°C (0.09°F) | 0.2°C(0.36°F) | -200 to +900°C (-328 to +1652°F) | 0.05°C (0.09°F) | 0.2°C(0.36°F) |
When using the internal reference junction (except couple B) add an additional uncertainty of 0.2 °C at 0°C.
It is possible (thermocouple B excepted) to choose by programming the cold junction localization: External at 0°C, internal (temperature compensation of instrument’s terminals) or manually entered.
Temperature coefficient: <10% of accuracy/°C
Display unit: °C and °F
C50 RTD Measurement and Simulation Range Specification Table
Download the Data Specification Sheet or the Users Manual for Complete Range and Accuracy Tables
Sensor Type | Temperature Input Range | Temperature Input Resloution | Accuracy 1 Year (Measurement) | Accuracy 1 Year (Simulation) |
---|---|---|---|---|
Pt50 (α = 3851) | -220 to +850°C (-364 to +1562°F) | 0.01°C | 0.012% RDG + 0.06°C(0.108°F) | 0.014% RDG + 0.18°C(0.324°F) |
Pt100 (α = 3851) | -220 to +850°C (-364 to +1562°F) | 0.01°C | 0.012% RDG + 0.05°C(0.09°F) | 0.014% RDG + 0.12°C(0.216°F) |
Pt100 (α = 3916) | -200 to +510°C (-325 to +950°F) | 0.01°C | 0.012% RDG + 0.05°C(0.09°F) | 0.014% RDG + 0.12°C(0.216°F) |
Pt100 (α = 3926) | -210 to +850°C (-328 to +1562°F) | 0.01°C | 0.012% RDG + 0.05°C(0.09°F) | 0.014% RDG + 0.12°C(0.216°F) |
Pt200 (α = 3851) | -220 to +600°C (-364 to +1112°F) | 0.01°C | 0.012% RDG + 0.12°C(0.216°F) | 0.014% RDG + 0.33°C(0.594°F) |
Pt500 (α = 3851) | -220 to +600°C (-364 to +1112°F) | 0.01°C | 0.012% RDG + 0.07°C(0.126°F) | 0.014% RDG + 0.18°C(0.324°F) |
Pt1000 (α = 3851) | -60 to +850°C (-364 to +1112°F) | 0.01°C | 0.012% RDG + 0.05°C(0.126°F) | 0.014% RDG + 0.08°C(0.144°F) |
Ni100 (α = 618) | -60 to +180°C (-76 to +356°F) | 0.01°C | 0.012% RDG + 0.03°C(0.54°F) | 0.014% RDG + 0.08°C(0.144°F) |
Ni120 (α = 672) | -40 to +205°C (-40 to +401°F) | 0.01°C | 0.012% RDG + 0.03°C(0.54°F) | 0.014% RDG + 0.08°C(0.144°F) |
Ni1000 (α = 618) | -60 to +180°C (-76 to +356°F) | 0.01°C | 0.012% RDG + 0.03°C(0.54°F) | 0.014% RDG + 0.08°C(0.144°F) |
Cu10 (α = 427) | -50 to +150°C (-58 to +302°F) | 0.01°C | 0.012% RDG + 0.18°C(0.324°F) | 0.014% RDG + 0.1°C(0.18°F) |
Cu50 (α = 428 | -50 to +150°C (-58 to +302°F) | 0.01°C | 0.012% RDG + 0.06°C(0.108°F) | 0.014% RDG + 0.15°C(0.27°F) |
Accuracies are given for 4-wire mounted probes
Take into account particular error of temperature sensor used and implementation conditions
Measuring current: 0.25 mA (Measurement) or from 0.1 to 1 mA (Emission)
Temperature coefficient: < 10% of accuracy/°C
C50 Process Calibrator Simulation DC Current
With or without Loop SupplyRange | Resolution | Accuracy/1yr |
---|---|---|
24 millamp | 1µA | 0.0175% RDG + 2 µA |
0 to 20 millamp | 1µA | 0.0175% RDG + 2µA |
4 to 20 millamp | 1µA | 0.0175% RDG + 2 µA |
Settling time: <5 ms
Specifications given for configurations in:
- Active mode (+24V ON) 1 Meter in passive mode (+24 V OFF)
- Passive mode (+24 V OFF) 1 Meter in active mode (+24 V ON)
C50 Process Calibrator Measurement DC Current
With or Without Loop SupplyRange | Resolution | Accuracy/1yr | Rin |
---|---|---|---|
0 to 20 millamp | 1µA | 0.0175% RDG + 2 µA | <25 Ω |
4 to 20 millamp | 1µA | 0.0175% RDG + 2 µA | <25 Ω |
±50 millamp | 1µA | 0.0175% RDG + 2 µA | <25 Ω |
Loop supply: 24V ±10%
HART® compatibility: Input impedance Rin = 280Ω
Display with linear or quadratic scaling
C50 Process Calibrator Simulation DC Voltage
Range | Resolution | Accuracy/1yr | Minimum Load |
---|---|---|---|
100 mV | 1 µV | 0.013% RDG + 3 µV | 1 kΩ |
2 Volts | 10 µV | 0.015% RDG + 20 µV | 2 kΩ |
20 Volts | 100 µV | 0.013% RDG +200 µV | 4 kΩ |
Temperature coefficient: < 7 ppm/°C beyond reference domain
Settling time: < 5 ms
C50 Process Calibrator Measurement DC Voltage
Range | Resolution | Accuracy/1yr | Rin |
---|---|---|---|
100 mV | 1 µV | 0.013% RDG + 3 µV | >10 MΩ |
1 V* | 10 µV | 0.013% RDG + 20 µV | >10 MΩ |
10 Volts | 100 µV | 0.015% RDG + 200 µV | >1 MΩ |
50 Volts | 1 mV | 0.015% RDG + 2mV | >1 MΩ |
(^) Specification domain: -0.8 V to +1 V
C50 Process Calibrator Simulation Frequency Pluse
Range | Resolution | Accuracy/1yr |
---|---|---|
1000 Hz | 0.01 Hz | 0.005% RDG |
10 kHz | 0.1 Hz | 0.005% RDG |
C50 Process Calibrator Measurement Frequency, Counting
Range | Resolution | Accuracy/1yr |
---|---|---|
20 kHz | 0.01 Hz | 0.005% RDG |
C50 Process Calibrator Simulation Resistance
Range | Resolution | Accuracy/1yr | Notes |
---|---|---|---|
40 Ω | 1 mΩ | 0.014% RDG + 3 mΩ 0.014% RDG + 10 mΩ |
10 mA 1mA |
400 Ω | 10 mΩ | 0.014% RDG + 20 mΩ 0.014% RDG + 30 mΩ |
10 mA 1mA |
4000 Ω | 100 mΩ | 0.014% RDG + 300 mΩ | 0.1/1 mA mA 1mA |
Current establishing time: < 1 ms
Notes: Current received by the calibrator
C50 Process Calibrator Resistance Measurement
Range | Resolution | Accuracy/1yr | Notes |
---|---|---|---|
400 Ω | 1 mΩ | 0.012% RDG + 10 mΩ | 10 mA 1mA |
4000 Ω | 10 mΩ | 00.012% RDG + 100 mΩ | 10 mA 1mA |
Accuracies are given for 4-wire mounted probes
Temperature coefficient: < 7 ppm/°C beyond reference domain
Open circuit terminal voltage: < 10 V
Continuity test: Open circuit for R > 1000 O and closed circuit for R < 1000 Ω
Measurement current: 0.25 mA
Eash C50 Multifunction Temperature Process Calibrator includes User manual, Battery charger, Set of 6 testing leads and carrying strap.