Secure Checkout
16T 1/16 DIN PID Autotune Controller with Thermocouple Or RTD Temperature Input

Thumbnail Filmstrip of 16T 1/16 DIN PID Autotune Controller with Thermocouple Or RTD Temperature Input Images

    16T 1/16 DIN PID Autotune Controller with Thermocouple Or RTD Temperature Input

    Overview

    The Athena Legacy 16 is a 1/16 DIN panel mounted, auto-tuning controller that can be used for precise control of a single temperature loop with two independent outputs. The controller accepts J, K, T, E, N, R and S Type Thermocouple, or PT100 Platinum 2-wire and 3-wire, 100 ohms at 0°C, (DIN curve standard 0.00385) RTD input. RS-232 or RS-485 communications are available, and two digital LED displays provide visual indication of various controller functions.
    Features
    • User-Selectable Ramp to Setpoint
    • Bumpless Auto/Manual Transfer
    • NEMA 4X (IP65) Dust and Splash-Proof Front Panel
    • On/Off through Full PID Operation (P,PI,PD,PID)
    • Auto-Tuning, Heat or Cool
    • Adjustable Hysteresis and Heat/Cool Spread
    • Optional Dual Output/Dual Alarm Capabilities
    • Optional Process Variable Retransmission
    • Optional Field-Configurable Process, Deviation, or Latching or Non-Latching Alarms
    • Remote Setpoint Select Option
    • cUL and CE Approvals
    Price Starting At:
    $310.00
    Need help? Contact us with questions.

      Shipping Click Add to Cart to Configure Input and Output Options
    Estimated Shipping 5 to 6 Weeks
    16T Autotune Temperature Controller Specifications
    Ambient Temperature 32°F to 131°F (0°C to 55°C)
    Relative Humidity Tolerance 90% non-condensing
    Line Voltage 100 to 250 Vac; 125 to 300 Vdc; 24 Vac/dc optional
    Power Consumption Less than 6 VA (instrument)
    Performance Specifications
    Accuracy +0.20% of full scale (+ 0.10% typical), + 1 digit
    Setpoint Resolution 1 count/0.1 count
    Repeatability ±1.0 count
    Temperature Stability 5 mV/°C maximum
    TC Cold End Tracking 0.05°C/°C ambient
    Noise Rejection 100 dB common mode; 70 dB series mode
    Process Sampling 10 Hz (100 ms.)
    Digital Filtering Adjustable 0.1 to 10
    Control Characteristics
    Setpoint Limits Span of Sensor
    Alarms Adjustable for high/low; selectable for process or deviation
    Proportional Band 2 to span of sensor
    Rate 0 to 960 sec.
    Reset 0 to 2400 sec.
    Cycle Time 0.2 to 120 sec
    Gain Ratio 0 to 2.0 (in 0.1 increments)
    Control Hysteresis 1 to 100 (on/off configuration)
    Spread (Output 2) 0 to 100 (above setpoint)
    Ramp to Setpoint 1 to 9999 min
    Auto-Tune Operator initiated from front panel
    Manual Control Operator initiated from front panel
    Mechanical Characteristics
    Display Dual 4-digit 0.36" (9.2 mm) LED
    Display Process Value Orange
    Setpoint Value Green
    Numeric Range -1999 to 9999
    Front Panel Rating EMA 4X (IP65)
    Front Panel Cutout 1.771" x 1.771" (45 mm x 45 mm)
    Connections Screw Terminals
    Outputs
    # 1 Reverse-acting (Heating) B: 5 A /3 A (120/240 Vac), normally open used for switching resistive loads
    G: 4-20 mA, full output to load 800 ohm impedance max
    S: 20 Vdc pulsed output for solid-state relays
    T: 1 A @ 120/240 Vac , solid-state relay, zero voltage-switched and optically isolated from drive signal
    Optional #2 Direct-acting (Cooling) B: 5 A /3 A (120/240 Vac), normally open used for switching resistive loads
    G: 4-20 mA, full output to load 800 ohm impedance max
    S: 20 Vdc pulsed output for solid-state relays
    T: 1 A @ 120/240 Vac , solid-state relay, zero voltage-switched and optically isolated from drive signal
    Input Types User Programmable
    Sensor Input Type J TC Range -328 to 1400°F
    -200 to 760°C
    Sensor Input Type K TC Range -454 to 2460°F
    -270 to 1349°C
    Sensor Input Type T TC Range -200 to 600°F
    -129 to 316°C
    Sensor Input Type E TC Range -238 to 1832°F
    -150 to 1000°C
    Sensor Input Type N TC Range -450 to 2370°F
    -268 to 1299°C
    Sensor Input Type R/S TC Range 0 to 3200°F
    -18 to 1750°C
    Sensor Input 100 ohm RTD Range -328 to 1562°F
    -200 to 850°C
    Sensor Input 100 ohm RTD Range -199.8 to 449.9°F
    -128.8 to 232.2°C
    The Legacy 16 Series controllers may be configured with Communication, Transducer Excitation and Auxiliary alarms options, Please contact us for details and ordering information.